Aerial

Aerial Aramid Aramid yarns

Application: aerial installation between poles and buildings
Ducting MT Aramid | Emcab
1

Central strength member (FRP rod)

2

Optical fiber

3

Gel-filled loose tube

4

Water-swellable yarns

4

Water-swellable yarns

5

Aramid yarns

6

Jacket

7

Ripcord

All-dielectric design

Low susceptibility to ice and wind loads

Reduced weight and size

Aerial installation on distribution and transmission lines up to 35 kV

Maximum rated design tension up to 10 kN with span lengths up to 200 meters

Wide range of operating temperatures. Installation temperature down to -30°C

Maximum rated design tension, kN 2
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 8.3 9.6 12.4
Cable weight, kg/km 50.3 65.7 112.7
Minimum bending radius, mm 125 144 186
Maximum rated design tension, kN 3
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 8.4 9.8 12.5
Cable weight, kg/km 52.7 68.9 113.8
Minimum bending radius, mm 126 147 188
Maximum rated design tension, kN 4
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 11.4 13.4 16.9
Cable weight, kg/km 97.6 129.3 206.3
Minimum bending radius, mm 171 201 254
Maximum rated design tension, kN 6
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 11.4 13.4 16.9
Cable weight, kg/km 99.4 130.5 206.3
Minimum bending radius, mm 171 201 254
Maximum rated design tension, kN 8
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 11.6 13.5 16.9
Cable weight, kg/km 103.1 134.0 207.6
Minimum bending radius, mm 174 203 254
Maximum rated design tension, kN 10
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 11.7 13.6 17.0
Cable weight, kg/km 106 136.4 211.0
Minimum bending radius, mm 176 204 255
Start shopping
Operating temperature -50°C ... +70°C
* -60°C ... +70 °C upon request
Installation temperature -30°C ... +70°C
Transportation and storage temperature -50°C ... +70°C
Minimum bending radius 15 x cable diameter
Design life 25 years