Aerial

Aerial Aramid DJ Aramid yarns double jacket (DJ)

Application: aerial installation between poles and buildings
Aerial Aramid DJ | Emcab
1

Central strength member (FRP rod)

2

Optical fiber

3

Gel-filled loose tube

4

Water-swellable yarns

5

Inner jacket

6

Aramid yarns

7

Jacket

8

Ripcord

Maximum rated design tension up to 100 kN

The most reliable among Aerial cables. Double tensile strength

Aerial installation on distribution and transmission lines up to 35 kV and above with tracking-resistant jacket

For construction of communication lines between towns and cities with distances between towers reaching 500 meters

Wide range of operating temperatures. Installation temperature down to -30°C

All-dieletric design

Maximum rated design tension, kN 4
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 12.8 14.8 18.3
Cable weight, kg/km 122.1 157.4 241.2
Minimum bending radius, mm 192 222 275
Maximum rated design tension, kN 6
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 12.8 14.8 18.3
Cable weight, kg/km 122.9 157.7 241.2
Minimum bending radius, mm 192 222 275
Maximum rated design tension, kN 7
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 12.9 14.8 18.3
Cable weight, kg/km 124.7 159.1 241.2
Minimum bending radius, mm 194 222 275
Maximum rated design tension, kN 8
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 12.9 14.9 18.3
Cable weight, kg/km 126.3 160.6 241.9
Minimum bending radius, mm 194 224 275
Maximum rated design tension, kN 10
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 13.0 15.0 18.4
Cable weight, kg/km 129.4 148.9 163.7
Minimum bending radius, mm 195 225 276
Maximum rated design tension, kN 12
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 13.3 15.1 18.5
Cable weight, kg/km 135.4 169.4 250.4
Minimum bending radius, mm 200 227 278
Maximum rated design tension, kN 15
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 13.8 15.6 18.8
Cable weight, kg/km 142.4 176.9 257.4
Minimum bending radius, mm 207 234 282
Maximum rated design tension, kN 20
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 14.2 16.0 18.4
Cable weight, kg/km 152.4 186.9 250.2
Minimum bending radius, mm 213 240 276
Maximum rated design tension, kN 25
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 14.7 16.4 19.5
Cable weight, kg/km 162.3 197.0 277.3
Minimum bending radius, mm 221 246 293
Maximum rated design tension, kN 30
Crush, kN/cm 0.22
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 15.1 16.7 19.9
Cable weight, kg/km 172.6 205.0 287.0
Minimum bending radius, mm 227 251 299
Start shopping
Operating temperature -50°C ... +70°C
* -60°C ... +70°C upon request
Installation temperature -30°C ... +70°C
Transportation and storage temperature -50°C ... +70°C
Minimum bending radius 15 x cable diameter
Design life 25 years